地铁维修基地杂散电流对埋地钢质管道的腐蚀及防护措施  被引量:25

Corrsion of Buried Steel Pipeline Caused by Stray Current from Subway Maintenance Base and Protective Countermeasures

在线阅读下载全文

作  者:颜达峰 刘乃勇[2] 袁鹏斌[2] 舒江[2] 李月娥[2] 

机构地区:[1]上海天然气管网有限公司,上海201204 [2]上海海隆石油管材研究所,上海200949

出  处:《腐蚀与防护》2013年第8期739-742,共4页Corrosion & Protection

摘  要:为了研究并掌握上海天然气管道主干网9标杂散电流干扰情况以及采取的相关保护措施,采用远程遥测设备监测燃气管道杂散电流干扰规律,同步测试了土壤电位梯度及管地电位。结果表明,地铁锦秋路维修基地泄漏电流是导致上海高压天然气管道9标管道杂散电流腐蚀的干扰源。现场检测了维修基地的相关电力装置性能,包括铁轨轨地电位、轨道绝缘情况、接地装置等,分析了地铁维修基地杂散电流的形成原因并提出了建议措施,包括加强铁轨绝缘施工与管理、加强变电站接地极的检测与管理以及对地极周边埋地管道采取排流保护等。In order to study and master the condition of the stray current of natural gas 9 section pipeline in Shanghai and take corresponding measures the impact of stray current on gas pipeline was monitored using remote measurement system. The cathodic protection potential and the magnitude of potential gradient on ground surface were simultaneous measured. The results indicate that the current leakage in the Jinqiu road subway maintenance base was the interference source of stray current upon Shanghai high-pressure natural gas 9 section pipeline. The rail potential, grounding, track to earth insulation and overhead power line were also tested. The causes for the current leakage in the subway maintenance base were analyzed, and protective countermeasures were proposed based on the measured results. The countermeasures inclucle to reinforce the construction and management of the rail insulation, the testing and measurement of the grounding electrode in the transformer substation, and the drained current protection.

关 键 词:地铁维修基地 杂散电流 远程遥测技术 同步测试 

分 类 号:TG174.41[金属学及工艺—金属表面处理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象