作 者:黄志强[1]
机构地区:[1]浙江省建德市疾病预防控制中心,浙江建德311600
出 处:《中国环境管理干部学院学报》2013年第4期64-67,共4页Journal of Environmental Management College of China
摘 要:采用真空采血管顶空填充柱气相色谱法测定水中三氯甲烷和四氯化碳,结果表明,三氯甲烷在10.0~50.0μg/L,四氯化碳在0.5~4.0μg/L浓度范围内呈良好线性关系,其r值分别为0.9994和0.9998;三氯甲烷和四氯化碳RSD分别在1.64%~2.27%和1.45%~2.40%之间;加标回收率分别在97.0%~103.5%和94.0%~103.2%之间。该方法操作简单,具有较好的灵敏度和准确度,适用于水中三氯甲烷和四氯化碳的检测。Vacuum blood collection tube was adopted to detect chloroform and carbon tetrachlo-ride in water by headspace gas chromatography. Results showed that the linear range of chloroform was 10.0~50.0μg/L and carbon tetrachloride was 0.5~4.0μg/L, which showed a good linear rela-tion. The r value was 0.999 4 and 0.999 8. RSD of chloroform and carbon tetrachloride was 1.64%~2.27% and 1.45%~2.40% respectively. Recoveries of chloroform and carbon tetrachloride were 97.0%~103.5% and 94.0%~103.2% respectively. This method is simple and has good precision and accuracy, and suitable for detecting chloroform and carbon tetrachloride in water.
关 键 词:真空采血管 三氯甲烷 四氯化碳 顶空气相色谱 水 填充柱
分 类 号:X832[环境科学与工程—环境工程]