检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗毅[1] 黄振宇[2] 刘路培[1] 黄善华[1] 罗翠琼[1] 龙春萍[1]
机构地区:[1]柳州市人民医院急诊科,广西柳州545006 [2]柳州市人民医院医务科,广西柳州545006
出 处:《华夏医学》2013年第4期765-768,共4页Acta Medicinae Sinica
摘 要:目的:探索超声引导在腋静脉穿刺置管术中的应用效果。方法:120急救中心接进来的危重患者50例,随机分为超声引导组和传统方法组,每组25例。超声引导组患者在超声引导下行腋静脉穿刺,传统方法组则采用解剖标记进行穿刺。记录两组的穿刺成功率、穿刺时间、试穿次数和穿刺并发症。结果:超声引导组穿刺成功率明显高于传统方法组,超声引导组穿刺时间和试穿次数明显少于传统方法组,超声引导组穿刺损伤并发症明显少于传统方法组。结论:超声引导可提高腋静脉穿刺成功率,缩短穿刺时间,降低穿刺并发症。Objective. To explore the application effect of ultrasound guided tube in the treatment of axillary vein puncture. Methods. 50 cases of critically ill patients in the 120 emergency center, were divided randomly into ultrasound group and the traditional method group, 25 patients in each group. Ultrasound guided group were guided axillary vein puncture under ultrasound, the tradition-al method group with anatomic markers for puncture. Recording two groups of the success rate of puncture, puncture time, try times and the number of puncture complications. Results. The suc-cess rate of ultrasound guidance was significantly higher than that of traditional method group punc-ture time and try times significantly less than traditional method group, ultrasound guided puncture injury obviously less than that of traditional method group. Conclusion. Ultrasound guidance can improve the success rate of axillary vein puncture, shorten the operation time, reduce the complica-tions.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3