沿海钢铁厂连铸二冷水喷嘴堵塞原因分析与对策  被引量:1

Cause Analysis and Countermeasures of Nozzle Clogging of Continuous Casting Secondary Cooling Water in Coastal Steel Mill

在线阅读下载全文

作  者:徐升[1] 

机构地区:[1]首钢京唐钢铁联合有限责任公司,河北唐山063200

出  处:《冶金动力》2013年第6期52-56,共5页Metallurgical Power

摘  要:炼钢连铸二冷水水质问题引起喷嘴堵塞,造成铸坯表面裂纹。以某钢厂板坯连铸机二冷水喷嘴堵塞现状为例,从水处理工艺、水源、水质及运行管理等方面进行分析,找出二冷水喷嘴堵塞的原因各影响因素,提出相应措施。The water quality problem of continuous casting secondary cooling water caused nozzle clogging and crack of slab surface. Taking continuous caster secondary cooling water of a steel source, water quality as well as operation management for example nozzle clogging of slab mill, the treatment process, water were analyzed. The nozzle clogging causes of secondary cooling water were found out and the corresponding measures were giv en.

关 键 词:连铸二冷水 喷嘴堵塞 原因分析 

分 类 号:TF085[冶金工程—冶金物理化学]

 