一种吞咽障碍压力测定治疗仪的设计与临床初步研究  被引量:3

The design and clinical preliminary study:A swallowing disorder pressure measurement and treatment equipment

在线阅读下载全文

作  者:冯珍[1] 帅浪[1] 张纯[2] 刘玲玲[1] 

机构地区:[1]南昌大学第一附属医院康复医学科,江西南昌330006 [2]南昌大学建筑工程学院工程力学实验中心

出  处:《中国康复医学杂志》2013年第8期723-726,共4页Chinese Journal of Rehabilitation Medicine

基  金:江西省科技厅重点课题(赣财政[2008]147号);江西省教育厅科技支撑项目(GJJ12066);江西省高等学校教改课题(JXJG-10-1-17)

摘  要:目的:针对咽期吞咽障碍环咽肌失弛缓的压力测量和定量扩张问题,设计开发吞咽障碍压力测定治疗仪并予以临床初步研究。方法:该装置的导管和膨胀气囊部分以导尿管结构为蓝本,选择硅胶作为气囊材料,制成三个独立气囊,上下两个气囊为定位气囊,通过中间气囊对环咽肌张力进行测量及垂直定向加压扩张。将之应用于两名受试者(环咽肌失弛缓患者1例和吞咽正常受试者1例)。结果:环咽肌失弛缓患者治疗前洼田饮水试验Ⅴ级,吞咽造影检查示环咽肌失弛缓,环咽肌压力值高;患者行扩张治疗5d后其临床症状明显好转,洼田饮水试验降至Ⅰ级,吞咽造影检查基本正常,环咽肌压力值明显下降。吞咽正常受试者洼田饮水试验Ⅰ级,吞咽造影检查示环咽肌正常,环咽肌压力值较环咽肌失弛缓患者低。结论:该吞咽障碍压力测定治疗仪数据测量简单可靠,患者无明显不良反应,医疗成本低,有较强的临床实用性。Objective: For the sake of pharyngeal dysphagia cricopharyngeal achalasia(CA) pressure measurement and quan- titative expansion, to design and develop a swallowing disorder pressure measurement and treatment equipment. Method: The equipment consisted of two parts: and made into three separated balloons, including catheter and inflation balloon, which was made of silicagel, two positioning balloons and one expanding balloon. The lat- ter was located in the middle of the formers. The middle balloon could be compressed for measuring the crico- pharyngeal muscle tension and expanding in vertical orientation. This technology was applied to two subjects(1 patient with CA and 1 subject with normal swallowing). Result:Before treatment, in the patient with CA Kubota water test was at V level; vedeofluoroscopic swallow- ing study(VFSS) showed CA and high cricopharyngeal muscle pressure. The patient was treated by balloon dila- tion for 5 days; after treatment the clinical symptoms improved signifcantly, Kubota water test was down to ] level, VFSS showed almost normal, the pressure of cricopharyngeal muscle decreased obviously. In the subject with normal swallowing, Kubota water test was at I level; VFSS showed the pressure of cricopharyngeal mus- cle was lower than the patient with CA.This wallowing disorder pressure measurement and treatment equipment is reliable, noninvasive and inexpensive. The only, but no side Author's address chang,procedure can be easily handled by clinicians, maybe cause the subjeet nlininlum discomfort effect. It has better clinical practical value. Dept. of Rehabilitation Medicine,The First Affiliated Flospital of Nanchang University, Nanchang, 330006

关 键 词:环咽肌失弛缓 压力测量 扩张治疗 吞咽障碍 吞咽造影检查 

分 类 号:R49[医药卫生—康复医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象