检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:谭帅霞[1] 邓江华[1] 昌慧娟[1] 刘国钧[1] 任申玥[1] 王进[1]
机构地区:[1]株洲时代新材料科技股份有限公司,湖南株洲412007
出 处:《涂料工业》2013年第8期50-54,共5页Paint & Coatings Industry
摘 要:讨论了氟树脂原料及涂料样品中溶剂可溶性氟含量的测定方法。首先以氧弹燃烧分解氟树脂,把其中的氟转化为氟离子,然后用离子色谱法定量分析溶剂可溶性氟含量。在扩展不确定度取包含因子2,置信率为95%时,氧瓶燃烧-电位滴定法测定结果均处于氧弹燃烧-离子色谱法测定不确定度区间中,表明2种检测方法结果同样有效可信,且氧弹燃烧-离子色谱法操作简单、准确可靠。The fluorine content measuring method in fluorocarbon resin and coatings were discussed. As fluorocarbon resin and coatings was decomposed by oxygen bomb combustion, to eouvert fluorine in the sample into ions, which was then determined by Ion chromatography. Additionally, the uncertainty of measurement was evaluated, and all the values measured by oxygen flask burning - potentionmetric titration were in the range of the uncertainty interval (with the coverage factor 2 under the 95% trusting probability) by oxygen bomb combustion -- ion chromatography. The results showed that these two methods were effective and credi- ble, and oxygen bomb combustion -- ion chromatography was easy, accurate and reliable.