微波消解氧化还原滴定法测定高碳铬铁中铬含量  被引量:1

Determination of Chromium Content in High Carbon Ferrochrome by Microwave Digestion-Redox Titrimetric

在线阅读下载全文

作  者:焦凤菊[1] 徐少华[1] 郭英英[1] 

机构地区:[1]中国一拖集团有限公司工艺材料研究所,河南洛阳471003

出  处:《铸造技术》2013年第8期1096-1098,共3页Foundry Technology

摘  要:通过微波消解法处理高碳铬铁样品,在最佳消解条件下使高碳铬铁样品溶解完全。冒硫酸烟赶尽溶液中的氟离子,采用氧化还原滴定法测定高碳铬铁样品中的铬含量。该法较碱熔融样品处理法快速、环保、准确,检测成本低,能够满足实验室日常检测的需要。The high carbon ferrochrome samples were treated through microwave digestion method, the sample of high carbon ferrochrome was dissolved completely in optimum digestion conditions. The fluoride ions in the solution were drived out by vitriolic smoke, The chromium content of high carbon and chromium was determined using a redox titration method. The method is faster than the alkali fusion sample processing method in accurate detection, environmental protection, and has low cost, can satisfy the daily laboratory testing needs.

关 键 词:微波消解 高碳铬铁 氧化还原滴定 

分 类 号:TF641[冶金工程—钢铁冶金]

 