Effect of repetitive square voltage frequency on partial discharge features  被引量:8

Effect of repetitive square voltage frequency on partial discharge features

在线阅读下载全文

作  者:WANG Peng WU GuangNing LUO Yang ZHU GuangYa 

机构地区:[1]School of Electrical Engineering,Southwest Jiaotong University

出  处:《Science China(Technological Sciences)》2013年第6期1313-1321,共9页中国科学(技术科学英文版)

基  金:supported by the National Natural Science Foundation of China (Grant Nos. 51177136, 50377035);the Zhuzhou Electric Motor Company of the South China Locomotive & Rolling Stock Corporation,Limited

摘  要:The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of c

关 键 词:inverter-fed motors partial discharge insulation system qualification test square voltages 

分 类 号:TM855[电气工程—高电压与绝缘技术]

 