检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]广东电网电力科学研究院,广东广州510600 [2]浙江大学电气工程学院,浙江杭州310027
出 处:《能源工程》2013年第4期16-19,共4页Energy Engineering
摘 要:分析了配电网各类防雷技术的技术性及经济性,针对10 kV电压等级配电网,提出了相应的防雷技术建议,涉及线路防雷和设备防雷两个方面,前者包括架空线路安装避雷线保护、线路避雷器保护以及架空绝缘线路"疏导式"防雷等,后者包括配电变压器防雷、变电所内的开关设备防雷以及户外线路开关设备防雷等,研究结果可为10 kV配电网的防雷提供参考。The technical and economic characteristics of various types of lightning protection technology were analyzed. Furthermore, the lightning technology proposals for 10 kV voltage level distribution network was given, including 10 kV distribution network line lightning protection and equipment lightning protection. And line lightning protection focused on the protection of overhead lines to install lightning conductor, line arrester protection and mediator-type lightning protection. Besides, equipment lightning protection focused on distribution transformers, substation switchgears and outdoor line switching equipments. The conclusions can provide references for the 10 kV distribution network lightning protection.
关 键 词:10 KV电压等级 配电网 线路防雷 设备防雷 技术经济性
分 类 号:TM732[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.31