检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:彭彬[1] 于浩[1] 苏韵掣 苏廷[1] 黄进[1] 邓晓勇[2]
机构地区:[1]国电南瑞科技股份有限公司,江苏省南京市210061 [2]江西省电力公司基建部,江西省南昌市330077 [3]四川大学电气信息学院,四川省成都市610064
出 处:《电力系统自动化》2013年第16期114-118,共5页Automation of Electric Power Systems
摘 要:根据目前变电站、电厂传统巡检方式存在的弊端,提出了一种可以实时定位人员位置,并根据不同位置提供多种服务的解决方案。比较了国内外多种定位系统,并总结了基于无源超高频电子标签定位的优势。系统根据物联网网络层次划分为感知层、网络层、应用层3层,分别阐述了感知层无源超高频电子标签的安置方案,网络层手持终端预处理感知对象数据,完成本地服务并将人员空间位置信息实时通过无线网络传递到应用层位置服务器,可以与厂站监控系统、智能变电站全景数据平台之间实现数据共享和智能联动。系统已实际应用于500kV智能变电站低压开关柜室和水电站廊道中,显著提高了人身安全性和厂站自动化水平。This paper proposes a solution for avoiding the disadvantages of the current patrol inspection system for power plant and substation, which can locate real-time the operators and offer different location based services. A variety of location systems at home and abroad are compared, and the advantages of the location system based on ultra-high frequency-radio frequency identification (UHF-RFID) passive tags are summarized. According to the network layers of the internet of things, the system is divided into three layers, namely, the perception layer, network layer, and application layer. Full account is given of the way the UHF-RFID passive tags are arranged in the sensor layer, preprocessing of the data in the portable terminal prior to rendering location based services, eventually transferring the acquired data to the interaction layer for sharing and cooperating smartly with the platform of panoramic data or the monitoring system. This method is successfully being applied to the low-voltage switehgear in a 500 kV smart substation project and the corridor in a hydropower station, which has improved personal security and the station automation level.
关 键 词:智能电网 智能厂站 超高频射频识别 无源电子标签 位置服务 物联网
分 类 号:TM76[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15