原子荧光光谱法测定锑及三氧化二锑中的痕量汞  被引量:1

Determination of Trace Mercury in the Antimony and Antimony Trioxide by Atomic Fluorescence Spectrometry

在线阅读下载全文

作  者:宋应球 吴东华 毛小红 李兵[2] 

机构地区:[1]锡矿山闪星锑业有限责任公司,湖南冷水江417502 [2]湖南有色金属研究院,湖南长沙410100

出  处:《湖南有色金属》2013年第4期69-72,共4页Hunan Nonferrous Metals

摘  要:提出和建立了原子荧光光谱法直接测定锑及三氧化二锑中痕量汞的方法,确定了分析条件。汞的浓度在0.25—2.00ng/mL范围内与荧光强度呈良好的线性关系,方法的检出限0.035ng/mL,结果相对标准偏差小于8.2%,回收率为98%~103%。该法已成为国家标准方法。The paper proposed and established the method of detect measurement in trace mercury by the atomic fluo- rescence spectrometry of antimony and antimony trioxide, and determinated the analytical condition. The concentration of mercury in 0.25 - 2.00 ng/mL range had good linear relationship with the fluorescence intensity, the limit of de- tection of it is at 0. 035 ng/mL, RSD of the measurement of it is under 8.2% and recovery in range of 98% - 103%. The law has become a national standard method.

关 键 词:原子荧光光谱法  三氧化二锑  

分 类 号:O657.31[理学—分析化学]

 