检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湖北省防雷中心,武汉430074
出 处:《价值工程》2013年第27期288-289,共2页Value Engineering
摘 要:加油加气站为易燃易爆场所,其防雷防静电尤为重要。雷电通过各种途径对该场所造成严重威胁。该场所不仅仅要防雷电,而且还要防静电。本文阐述了加油加气站的综合防护技术,通过计算、分析,得出雷电反击带来的危害。结果表明:在实际的防雷设计过程中应当考虑防雷设计的余量,方可足够将灾害的风险降低到最小。Petrol and gas stations are flammable and explosive place, so that its anti-lightning and anti-static is particularly important. Lightning is a serious threat to the place by various means. Measures should be taken against for lightning and static. This paper describes the comprehensive protection technology about petrol and gas stations. Calculation and analysis shows that lightning counterattack is harm to the flammable and explosive place. The result is that the process of engineering design should be considered in safety margin in practical, then it will be sufficient to minimize the risk of disaster.