回转式空气预热器漏风监测的研究进展  被引量:2

Research Progress on Air-Leakage Monitoring of Rotary Air Preheater

在线阅读下载全文

作  者:杨平[1] 陈岩[1] 刘秀杰[1] 

机构地区:[1]上海电力学院自动化工程学院,上海200090

出  处:《电力与能源》2013年第4期325-328,共4页Power & Energy

基  金:上海市科委2010创新行动计划项目(10250502000)

摘  要:为解决当前的回转式空气预热器漏风的在线监测难题,回顾了十多年有关同转式空气预热器漏风的研究工作,综合分析结论是:回转式空气预热器漏风主要是直接漏风,其漏风量与泄漏系数、漏风面积和漏风压差成正比,漏风性能主要用漏风率指标来衡量,漏风率的测试主要依靠空气预热器烟气通道进出口烟气成分测试实验技术。虽然已有两种漏风分布计算模型和一种软测量监测方法提出,但还不能用于实际在线监测。建议用烟气成分测试法来实现回转式空气预热器漏风率的在线监测。To solve the current problems of the air-leakage monitoring of rotary air preheater, this paper has reviewed the recent ten years' researches about the air-leakage of rotary air preheater. We get the following integrated analysis conclusions: the main leakage lies in the direct air leakage, and its volume is proportional to the leakage coefficient, the area and differential pressure of leakage air; the air-leakage performance is mainly measured by the air leakage rate which is tested mainly rely on the measure technique of the import and export flue gas composition in flue gas channel of rotary air preheater. Although there are two computing models of the air-leakage distribution and a soft measuring and monitoring method have been proposed, they cannot be used for online monitoring. It is suggested that using the gas composition test method to realize the online monitoring of rotary air preheater air leakage rate.

关 键 词:漏风 回转式空气预热器 锅炉 监测 

分 类 号:TP13[自动化与计算机技术—控制理论与控制工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象