检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:丁自更[1] 于俊峰[1] 尹端沚[1] 胡伟清 汪勇先[1] 王根凤[2] 张茹萍[2] 来文[2] 谢弘[2]
机构地区:[1]中国科学院上海原子核研究所,上海201800 [2]中国科学院上海细胞生物研究所,上海200031
出 处:《核技术》2000年第11期762-766,共5页Nuclear Techniques
摘 要:以含葡萄糖酸钠配体的SnCl2为还原液,还原Na188ReO4后,标记人血清IgG,在pH=3的条件下, 1g/L的蛋白质用高于5000倍摩尔过量的抗坏血酸(AA)还原2h后,与2.6×10-2-8.0×10-2mol/L的SnCl2-葡萄糖酸钠溶液及188-ReO4-反应3h,可以得到90%的标记率,在该标记条件下,对影响标记率的因素作了初步的研究和探讨。SnCl2 reduction solution together with sodium gluconate was chosen to reduce Na188ReO4- and label human IgG. The labelling conditions were optimized. It was found that the labelling efficiency could reach 90% under the following condition: 1g/L protein with 5000 mole ratio AA in 2h reducing time at pH= 3, in mingled with 2.6×10-2- 8.0× 10-2mol/L SnCl2 in sodium gluconate and 188ReO4- at ambient temperature. The factors effecting labelling efficiency were studied and discussed.
关 键 词:标记率 人血清白蛋白 铼^188标记 放射性核素
分 类 号:R817.8[医药卫生—影像医学与核医学]