检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《中南大学学报(医学版)》2013年第8期853-856,共4页Journal of Central South University :Medical Science
摘 要:目的:评价B超引导下经皮肾镜Cyberward双导管碎石术和气压弹道联合超声碎石术对于鹿角形肾结石的疗效。方法:前瞻性地将138例鹿角形肾结石患者随机分成双导管组(A组,n=71)和弹道联合超声组(B组,n=67)。比较两组间术前资料、手术时间、出血量、住院时间、住院费用、并发症。结果:两组均成功建立通道并且行一期碎石,术前两组间结石大小、年龄构成、合并症等均未见差别。术中碎石时间A组明显短于B组[(77.14±21.39)vs(84.25±20.62)mL,P=0.049],术中出血量以及术后诸指标差异无统计学意义。两组一期结石清除率分别为67.6%和70.1%,差别无统计学意义(P=0.854)。结论:两种碎石方法对于鹿角形肾结石均安全有效。双导管碎石术更加高效,操作更简单。Objective: To evaluate and compare the efficiency and safety of Cyberwand dual probe lithotriptor and Swiss lithoclast master in percutaneous nephrolithotomy for renal staghorn calculi. Methods: A total of 138 patients with renal staghom calculi were divided randomly into a Cyberwand dual probe lithotripter group (Group A, n=71) and a Swiss lithodast master group(Group B, n=67). The data for operative time, blood loss volume, one-stage calculus clearance rate, hospitalization time, cost of hospitalization and complication in the two groups were collected and compared. Results: The renal access was established successfully and the one-stage percutaneous nephrolithotomy (PCNL) was performed in the 2 groups. There was no significant difference in the size of stones, the age of patients and the complications between the 2 groups before theoperations. Intraoperative gravel time in the Group A was significantly shorter than that in the Group B (77.14±21.39 vs 84.25±20.62, P=0.049). There was no significant difference in the one-staged stone dearance rate, blood loss volume in the operation between the 2 groups. The one-staged stone clearance rate in the 2 groups were 67.6% (48/71) and 70.1% (47/67) respectively, with no significant difference (P=0.854). Conclusion: Two lithotrities were safe and efficient for renal staghorn calculi. But comparing with Swiss lithodast master, Cyberwand dual probe lithotriptor is more efficient and convenient.
关 键 词:Cyberward双导管 弹道合并超声 鹿角形肾结石
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249