电感耦合等离子体质谱法测定血清镁  被引量:2

Determination of magnesium in serum by inductively coupled plasma mass spectrometry

在线阅读下载全文

作  者:闫颖[1] 汪静[1] 赵海舰[1] 胡翠华[1] 马嵘[1] 张江涛[1] 陈文祥[1] 张传宝[1] 

机构地区:[1]卫生部北京医院卫生部临床检验中心,100730

出  处:《中华检验医学杂志》2013年第8期738-742,共5页Chinese Journal of Laboratory Medicine

基  金:国家高技术研究发展计划资助项目(2011AA02A102,2011AA02A116);国家科技支撑计划资助项目(2012BA137801)

摘  要:目的建立一种应用电感耦合等离子体质谱(ICP—MS)测定血清中镁(Mg)含量的候选参考方法。方法验证性研究。以铝(Al)作为Mg的内标,用重量法加入到标准溶液和血清中,样品经过硝酸消解、稀释,以ICP—MS测定其^27Mg/^27Al同位素比值,选择与样品相邻的一对标准溶液校准样品中Mg的浓度,采用包括法定量。对方法的线性范围、精密度、回收率以及正确度进行验证,并计算测量不确定度,参加国际比对。结果该方法的线性范围为0~0.5¨g/g(R。=0.99998),测定2份血清中Mg的分析回收率分别为100.22%和100.11%(n=3),测定3份血清的重复性CV分别为0.35%、0.36%和0.41%(n=9)。正确度验证显示测定标准参考物质SRM909b和SRM956b的结果均在认定值范围内,SRM909b两水平血清测定总变异系数分别为0.54%、0.53%,SRM956b三水平血清测定总变异系数分别为0.30%、0.50%和0.47%。参加国际参考实验室间比对结果理想。结论本研究建立了ICP—MS测定血清Mg的测量程序,具有良好的线性范围、精密度和回收率,且此法操作简单快速,有望成为血清Mg测定的候选参考方法。Objective To develop a candidate reference method for the determination of magnesium in serum by inductively coupled plasma mass spectrometry method (ICP-MS). Methods Aluminum was selected as internal standard of magnesium and spiked gravimetrically into magnesium standard solutions and serum samples. Then the 24 Mg/27 Al isotope ratios of digested and diluted samples were obtained by ICP-MS, the magnesium concentrations in serum were calibrated basing on the bracketing method. Results The analytical recoveries for 2 samples were 100. 22% and 100. 11% respectively (n = 3). The precision for 3 samples were 0. 35% , 0. 36% and 0. 41% respectively ( n = 9 ) . The results on Standard Reference Materials SRM909b and SRM956b gave excellent agreement with the certified values. The results of SRM909b gave the coefficients of variation (CV) of 0. 54% and 0. 53% for 2 samples, and the results of SRM956b gave 0. 30%, 0. 50% and 0. 47% for 3 samples. The method has been successfully applied to the RELA inter-laboratories comparison. Conclusions The ICP-MS method is proved to be not only precise and accurate, but also quick and convenient for measuring magnesium in serum. It is promising to be a candidate reference method.

关 键 词: 质谱分析法 分光光度法 原子 

分 类 号:R446.1[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象