检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]广东电网公司梅州供电局,广东梅州514021 [2]华南理工大学,广东广州510641
出 处:《电力电容器与无功补偿》2013年第4期11-14,24,共5页Power Capacitor & Reactive Power Compensation
摘 要:文章提出一种基于PC集群的并行无功优化系统,利用并行运算特点快速有效地求解系统无功优化问题。它采用C/S结构将多个客户端分别安装到多个计算机中,进行单独的无功优化计算。服务器负责参数设置、计算控制,并根据客户端运算能力合理分配计算量。通过在某地区电网的应用表明,该系统有效地提高了无功优化质量,大大地减少计算时间。In this paper, a kind of PC cluster-based parallel reactive power optimization system is proposed, which using parallel computing features quickly and efficiently solve reactive power optimization issue of the system. The C/S structure is used to install multiple clients into multiple computers and perform independent reactive power optimization computation. The server is responsible for parameter setting, calculation control and, according to the client computing capacity, reasonably distribute computation amount. The application in certain regional power grid is shown that the system improves effectively quality of the reactive power optimization and reduces greatly the computation time.
分 类 号:TM714.3[电气工程—电力系统及自动化]