检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]江苏达胜加速器制造有限公司,吴江215214 [2]苏州大学辐照技术研究所,吴江215200
出 处:《辐射研究与辐射工艺学报》2013年第4期57-59,共3页Journal of Radiation Research and Radiation Processing
摘 要:本工作对医疗保健产品采用电子加速器辐射灭菌的关键因素进行了探讨。通过对ISO11137标准的理解以及在实践中得出的经验,确定了电子加速器安装鉴定中需要形成的文件运行鉴定、性能鉴定及常规监控方法。安装鉴定、运行鉴定、性能鉴定及常规监控构成了电子束对医疗保健产品辐射灭菌过程控制的关键要素。The key factors involved in the sterilization of health-care products irradiated by electron accelerators were investigated in this paper based on the requirements of/SO 11137 and the experiences in practice. The files should be constructed in installation qualification (IQ), the general method used to do the operational qualification (OQ), performance qualification (PQ) and routine monitoring. IQ, OQ, PQ and routine monitoring were the bases of the process control of sterilization while the irradiation of health-care products was performed by electron accelerators.
关 键 词:辐射灭菌 医疗保健 安装鉴定 运行鉴定 性能鉴定 常规监控
分 类 号:TL54[核科学技术—核技术及应用]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30