300MW四角布置切圆燃烧锅炉变工况运行试验研究  

Experimental Research on Operating Performance of a 300 MW Tangentially Corner-Fired Boiler in Variable Load Operation

在线阅读下载全文

作  者:庄恩如[1] 袁益超[2] 冯景源[1] 陈朝晖 

机构地区:[1]上海锅炉厂有限公司,上海200240 [2]上海理工大学,上海200093

出  处:《能源研究与信息》1999年第4期18-23,共6页Energy Research and Information

摘  要:本文通过对某300MW四角布置切圆燃烧锅炉在不同省煤器出口氧量及磨煤机投运方式等工况下水平烟道内烟温分布及锅炉效率的热态试验结果的分析,指出了四角布置切圆燃烧锅炉水平烟道内烟温分布随省煤器出口氧量及磨煤机投运方式的变化特点及运行工况的变化对锅炉效率的影响.This paper describes the analysis of the experimental results of the flue-gas temperature distribution in the horizontal flue and the efficiency of a 300 MW tangentially corner-fired boiler in variable load operation. The effect of the oxygen content at the economizer outlet and the operation of coal pulverizing mills on the flue-gas temperature distribution in the horizontal flue was investigated. The impact of variable load operation on the boiler efficiency was analyzed as well.

关 键 词:四角布置切圆燃烧锅炉 变工况 电站锅炉 运行 

分 类 号:TM621.2[电气工程—电力系统及自动化] TK227[动力工程及工程热物理—动力机械及工程]

 