摘 要:为了比较不同型号吸烟机对卷烟主流烟气释放量检测结果的差异,分别使用RM200A和RM20H转盘式吸烟机在同一实验条件下对4个样品进行检测,并对卷烟主流烟气释放量(总粒相物、水分、焦油、烟气烟碱、烟气一氧化碳)及抽吸口数进行差异性分析.结果表明:RM200A所测样品结果的相对标准偏差小于RM20H所测结果;RM200A测定卷烟样品的CO低于RM20H所测结果,两者有显著性差异;盒标值7 mg以上样品,RM200A所测水份低、烟碱高.The effects of different types of smoking machine on releasing amount of mainstream smoke were investigated. Under the same condition,4 samples were tested by using RM200A and RM20H smoking machine, respectively. After difference analysis on releasing amounts of TPM, moisture, tar, nicotine and CO in mainstream smoke and puff number, the results showed that the repeatability of results got from RM200A on releasing amounts of mainstream smoke was better than RM20H. For the same sample ,the CO testing result from RM20H was greater than that from RM200A,both have significant differences. The nicotine content testing results from RM200A were greater than that from RM20H, and moisture content was just the opposite above the 7 mg samples.