PF-55翻盘真空过滤机的故障分析与技改措施  被引量:1

Failure Analysis and Improvement Measures for the PF - 55 Tilted-pan Vacuum Filters

在线阅读下载全文

作  者:康启星 

机构地区:[1]陕西华山化工集团复合肥公司,华县714100

出  处:《硫磷设计与粉体工程》2000年第6期35-38,共4页Sulphur Phosphorus & Bulk Materials Handling Related Engineering

摘  要:针对PF-55翻盘真空过滤机运行中出现的转盘被腐蚀、不锈钢滤板产生裂纹、滤盘大端连接板焊缝开裂等问题,分析了故障发生的原因,并提出技改措施。运行证实这些措施是行之有效的,满足了湿法磷酸装置挖潜、增产、增效的要求。In order to address operation problems of the PF- 55 tilted-pan vacuum filters,including corrosion of tilted pan, crack of stainless steel filter plate,disjoint of weld seam of the connection plate at the larger end of the filter pan,the author analysis the causes of failures and proposes improvement measures. Operation practice demonstrates that these measures are effective and meet requirements for wet-process phosphoric acid plants to tap the potential, to increase production volume and to improve effects.

关 键 词:真空过滤机 翻盘过滤机 湿法磷酸 过滤 故障处理 