检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄丽[1,2] 潘忠厚[2] 黄长春[2] 涂星朋[2] 林海霞[2] 黄宗平[2]
机构地区:[1]厦门大学化学化工学院化学系,福建厦门361005 [2]厦门出入境检验检疫局,福建厦门361026
出 处:《化学分析计量》2013年第5期17-19,共3页Chemical Analysis And Meterage
基 金:国家质检总局科技计划项目(2012IK124)
摘 要:建立了树脂工艺品中半挥发性有机物(SVOCs)的超声萃取-气相色谱检测方法。对超声萃取条件进行了研究,优化了气相色谱参数。结果表明,样品用三氯甲烷在60℃下超声萃取40min,选择HP-5色谱柱时,气相色谱(FID)测定半挥发物总量时可获得良好的灵敏度和准确的定量结果。方法的相对标准偏差小于5%(n=6),检测限为2mg/kg。4个含量水平样品的6个实验室3次平行测定结果表明,实验室内测定结果的相对标准偏差为1.61%~2.94%,实验室间测定结果的相对标准偏差为5.96%-8.35%。A method was developed for determination of the semi-volatile organic compounds(SVOC) in resin craft by ultrasonic extraction-gas chromatography(GC). The ultrasonic extraction conditions were investigated and GC parameters were optimized. Test results showed that good sensitivity and accurate quantitative performances were achieved by GC-FID when the samples were ultrasonic-extracted with chloroform for 40 min at 60 ~C and HP-5 capillary was used. The relative standard deviations(RSDs, n=6) of actual samples were all less than 5% and the detection limit was 2 mg/kg. RSDs of the determination results for 4 content levels were 1.61%-2.94% by datas from a lab, and 5.96%-8.35% by datas from different labs, which were calculated according to the test results of 3 replicates by 6 labs.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.21.114.165