机构地区:[1]Biomedical Engineering Program, Sun Yat-sen University [2]Shenzhen Institutes of Advanced Technology [3]The Shenzhen Key Laboratory for Low-cost Healthcare
出 处:《Journal of Central South University》2013年第9期2423-2431,共9页中南大学学报(英文版)
基 金:Project(2012M510207)supported by the China Postdoctoral Science Foundation;Projects(60932001,61072031)supported by the National Natural Science Foundation of China;Project(2012AA02A604)supported by the National High Technology Research and Development Program of China;Project(2013ZX03005013)supported by the Next Generation Communication Technology Major Project of National Science and Technology,China;Project supported by the"One-hundred Talent"and the"Low-cost Healthcare"Programs of Chinese Academy of Sciences
摘 要:Respiratory monitoring is increasingly used in clinical and healthcare practices to diagnose chronic cardio-pulmonary functional diseases during various routine activities.Wearable medical devices have realized the possibilities of ubiquitous respiratory monitoring,however,relatively little attention is paid to accuracy and reliability.In previous study,a wearable respiration biofeedback system was designed.In this work,three kinds of signals were mixed to extract respiratory rate,i.e.,respiration inductive plethysmography(RIP),3D-acceleration and ECG.In-situ experiments with twelve subjects indicate that the method significantly improves the accuracy and reliability over a dynamic range of respiration rate.It is possible to derive respiration rate from three signals within mean absolute percentage error 4.37%of a reference gold standard.Similarly studies derive respiratory rate from single-lead ECG within mean absolute percentage error 17%of a reference gold standard.Respiratory monitoring is increasingly used in clinical and healthcare practices to diagnose chronic cardio-pulmonary functional diseases during various routine activities.Wearable medical devices have realized the possibilities of ubiquitous respiratory monitoring,however,relatively little attention is paid to accuracy and reliability.In previous study,a wearable respiration biofeedback system was designed.In this work,three kinds of signals were mixed to extract respiratory rate,i.e.,respiration inductive plethysmography (RIP),3D-acceleration and ECG.In-situ experiments with twelve subjects indicate that the method significantly improves the accuracy and reliability over a dynamic range of respiration rate.It is possible to derive respiration rate from three signals within mean absolute percentage error 4.37% of a reference gold standard.Similarly studies derive respiratory rate from single-lead ECG within mean absolute percentage error 17% of a reference gold standard.
关 键 词:respiration inductive plethysmography respiratory rate ELECTROCARDIOGRAM 3D acceleration activity
分 类 号:TH789[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...