检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:洪锦清[1] 陈明[1] 李敬[1] 程玉龙[1] 王瓒[1]
出 处:《检验检疫学刊》2013年第5期7-9,76,共4页Journal of Inspection and Quarantine
基 金:国家质检总局科技计划项目(2010IK099)
摘 要:建立了用离子色谱-电感耦合等离子体质谱法检测玩具材料迁移液中六价铬的新方法。采用阴离子交换色谱柱、中性NH4NO3淋洗液,结合梯度洗脱和碰撞反应池技术。实验表明,本方法可以很好地分离溶液中的三价铬和六价铬。当进样量为100μL时,对溶液中六价铬的检出限达到0.02μg/L。本方法灵敏度高,线性范围宽,加标回收率接近100%,能够满足新指令对玩具材料中可迁移六价铬的检测要求。To cope with the new EU toy safety directive, we developed a new method based on ion chromatography combined with inductively coupled plasma mass spectrometry (IC-ICP-MS) to measure chromium (VI) in the migration solution of toy materials. This method engaged IonPac AG11 anion-exchange column and neutral NH4NO3 mobile phase, with gradient elution and collision cell technology. The results showed that chromium (III) and chromium (VI) could be separated very well. A limit of detection of 0.02μg/L for chromium (VI) was obtained with an injection volume of 100μL. This method is of high sensitivity, wide linearity range, and good recovery rate (approaching 100 %), which can meet the requirements of new directive for determination of migratable chromium (VI) in toy materials.
关 键 词:六价铬 玩具 离子色谱 电感耦合等离子体质谱
正在载入数据...