检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]广东省绿色能源技术重点实验室(华南理工大学电力学院),广东省广州市510640
出 处:《电网技术》2013年第10期2771-2777,共7页Power System Technology
基 金:国家高技术研究发展计划(863计划)项目(2012AA050201)~~
摘 要:定量评估省级电网的无功调控能力以确定关口无功功率控制范围,是大电网自动电压控制(automatic voltage control,AVC)的关键。基于电网分层解耦的理念,首先给出了平均协调功率因数限值(average coordination power factor limits,ACPF)的定义来评价省级电网的无功承受极限,并求解ACPF的优化数学模型,得到ACPF与省级电网下送负荷水平的相关性曲线;接着根据各500 kV变电站负荷的差异性,近似线性化计算上游关口协调功率因数限值,并以其为约束条件建立下游关口协调功率因数下限值的计算模型及其快速估算方法,实现AVC系统参数的动态整定;最后给出了AVC系统省地协调的关口无功功率控制实现方法。应用到广东某区域电网的仿真结果表明,所提的方法在节能降损、提升电压质量、提高省级电网电压无功安全裕度以及挖掘片区变电容量等方面优势更加明显。It is the key problem in automatic voltage control(AVC) of large-scale power grids to quantitatively assess the reactive power regulation capability of provincial power grid to determine the control range of reactive power at the gateway of provincial power grid. Based on the idea of layered decoupling, firstly the definition of average coordination power factor limits(ACPF) is given to evaluate the limit of provincial power grid to withstand the reactive power, and the optimized mathematical model of ACPF is solved to obtain the correlation curve between ACPF and load level transmitted from provincial power grid to subordinate power networks; then based on the differences among loads of 500kV substations, the approximate linearization calculation of limit value of the coordinated power factor at main gateway is performed, and taking it as the constraint a calculation model and its fast estimation method for the lower limit value of coordinated power factor at subordinate gateway are established to implement dynamic setting of parameters of AVC system; finally a method to implement the AVC system based coordinated reactive power control at the gateway between provincial power grid and regional power grid is given. Simulation results of applying the proposed method to a certain regional power grid in Guangdong power grid show that the proposed method is favorable for energy-saving and loss-reduction, improving voltage quality, enhancing security margin of voltage and reactive power in provincial power grid and bringing the potential of area substation capacity into play.
关 键 词:功率因数 电压调控 自动电压控制 协调控制 无功功率
分 类 号:TM734[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.100.3