作 者:汪平分
机构地区:[1]中国移动福建公司泉州分公司,福建泉州362000
出 处:《通信电源技术》2013年第5期61-63,共3页Telecom Power Technology
摘 要:蓄电池组是通信基站供电系统的重要组成部分,也是最后一道保障。判断蓄电池性能的好坏最直接可靠的方法就是进行放电测试。泉州移动利用模拟量监控和开关电源具有的遥调功能,实现基站电池远程在线核对性放电测试,再运用蓄电池Peukert经验公式,通过对蓄电池典型放电曲线的分析完成蓄电池容量的简单分析,可以节省人力物力。The battery unit is an important constituent ot the communication station power supply system, out tabu mc final protection. The most direct and reliable method to judge battery performance good or bad is discharge test. Quanzhou mobile using analog monitor with the remote adjustment ruction in the switching mode power supply, realized the remote online battery discharge test of the base station, and by Peukert empirical formula, simply analyzed the battery capacity through analysis of a typical discharge curve of the battery, it can save manpower and resources.
关 键 词:Peukert电池经验公式 典型放电曲线 电压遥调