测定水质总氮时影响空白吸光值的因素  

Factor of Influencing Blank Absorbency on Determination of Total Nitrogen in Water

在线阅读下载全文

作  者:呼德拉提.阿那斯 孙世萍[1] 陈韩飞[1] 

机构地区:[1]新疆维吾尔自治区水产科学研究所,新疆乌鲁木齐830052

出  处:《水产学杂志》2013年第5期53-56,共4页Chinese Journal of Fisheries

摘  要:依据GB 11894-89,对测定水质总氮时空白吸光值过高的现象进行了分析。对不同纯度的K2S2O8试剂,不同等级的试验用水,不同方式洗涤的玻璃器皿和不同消解时间等四项因素进行了比对试验,结果选用经阴阳离子交换树脂处理的去离子水,(1+35)H2SO4浸泡的玻璃器皿和纯度大于99.0%的进口K2S2O8试剂及优级纯氢氧化钠试剂配成的碱性K2S2O8消解液和消解时间为30min条件下测得结果的空白吸光值为最优条件。According to GB 11894-89, the blank absorbency of total nitrogen in water was always higher than the standard data (0.03), So the phenomenon was analyzed o The contrastive experiments were made and the result were influenced by the four different factors, reagent purity, grade trial water, way of wash the glassware and digestion time. The optimal condition is using ultra water, immersing the glassware in (1 +35) H2SO4, purity of K2S208 and NaOH (GR), 30min' s dispel time.

关 键 词:总氮 空白吸光值 碱性K2S2O8 紫外分光光度法 

分 类 号:S959[农业科学—水产养殖]

 