检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海市电力公司检修公司直流运检中心,上海201708
出 处:《电力与能源》2013年第5期468-470,共3页Power & Energy
摘 要:在介绍换流站低压直流系统的组成、作用以及重要性的基础上,对上海南桥换流站2013年低压110V直流系统改造做了简单回顾。叙述了改造前南桥换流站低压直流系统的运行状况、控制策略以及存在问题,从站内运行维护角度出发,对低压直流系统改造方案进行了补充和完善。特别是通过比对新老系统在直流接地故障上的不同排查方法,证实了老站实施低压直流系统改造的可行性和必要性。On the base of the structure, function and importance of the low voltage DC system to the convertor station, this paper gives a brief review on the reconstruction programme of the low voltage 110 V DC system to Shanghai Nanqiao convertor station, in 2013. Firstly, it describes the operating condition, control strategy and the existing problems of the low voltage DC system on Nanqiao convertor station before the reconstruction pro- ject. FurthermOre, from the perspective of operation and maintenance to the convertor station, the reconstruction proposal of the low voltage DC system is supplymented and improved. Especially, through the different testing methods on the DC system grounding fault by comparison with the new and the old system, it demonstrates the feasibility and necessity of the reconstarction programme on the old low voltage DC system to this convertor station.
关 键 词:低压110 V直流系统 接线排查方式 故障定位 母线绝缘检测 技术改造
分 类 号:TM732[电气工程—电力系统及自动化]