新型静态混合器降解性能实验研究  被引量:1

Experimental Study on Degradation Performance of New Static Mixers

在线阅读下载全文

作  者:刘仁桓[1] 袁丁[1] 崔洪志[2] 王云峰[1] 王金花[1] 金有海[1] 

机构地区:[1]中国石油大学(华东) [2]中国石油辽河油田锦州采油厂

出  处:《化工机械》2013年第5期557-560,共4页Chemical Engineering & Machinery

摘  要:针对目前三次采油注聚物现场使用的静态混合器对聚丙烯酰胺(PAM)剪切降解大的缺点,研究设计了一种减少切割分离作用的静态混合器,通过剪切降解实验得出,PAM溶液的降解率随叶片单元数目的增大而增加,随着叶片角度的增加而减少,与流量近似成线性关系;优选出降解率小于2%的内管长度与叶片角度的尺寸优化组合,叶片角度为90°的内管长度最长。Considering the big shear degradation in mixing polyacrylamide (PAM) caused by static mixer for the tertiary oil recovery,a special static mixer for mixing polymer was designed to reduce shearing effect.The degradation experiment shows that PAM solution degradation rate increases with the number of leaf unit and decreases with the increase of blade angles,as well as approximates the linear relationship with the flow.Optimizing both inner tube length and leaf blade angle shows that when the degradation rate becomes less than 2% and the blade angle stays at 90°,the inner tube has the longest length.

关 键 词:静态混合器 三次采油 降解率 聚丙烯酰胺 

分 类 号:TQ051.71[化学工程]

 