X射线荧光光谱法用于催化剂中贵金属含量分析  

Analysis of the precious metal contents in the catalysts by X-ray fluorescence spectrometry

在线阅读下载全文

作  者:吴丽威[1] 赵飒[1] 王长发[1] 

机构地区:[1]西北化工研究院,陕西西安710061

出  处:《工业催化》2013年第10期63-65,共3页Industrial Catalysis

摘  要:通过对X射线荧光光谱法测定催化剂中贵金属含量的研究,模拟样品组分含量和制备条件自制一系列标样,绘制工作曲线。对催化剂中Pt和Pd含量进行测定,结果与国标法分析值相符,精密度良好。The contents of the precious metals in the catalysts were determined by Xray fluorescence spectrometry. A series of standard samples were made by simulating the sample preparation process and contents, and then the standard curves were drawn. The test results of Pt and Pd contents of the catalyst measured by XRF method were basically consistent with that obtained by GB standard method. The preci sion of XRF method was good.

关 键 词:催化剂工程 X射线荧光光谱法 PT催化剂 PD催化剂 工作曲线 