检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]兰州交通大学环境与市政工程学院,甘肃兰州730070 [2]中国石油兰州化工研究中心,甘肃兰州730060
出 处:《石化技术与应用》2013年第6期522-525,共4页Petrochemical Technology & Application
基 金:中国石油科技部资助项目(项目编号:2008 D-4707)
摘 要:采用Fenton试剂法预处理丁苯橡胶废水,通过正交实验考察了影响处理效果的主要因素。结果表明,双氧水用量是主要影响因素。在反应温度为45℃,反应时间为60min,pH值为3~7,FeSO4·7H2O用量为3.3mmol,双氧水用量为4.0mL,总离子摩尔浓度不变的条件下,Cu^2+,BO3^3-,Mn^2+均能与Fe^2+发生络合反应,达到较好的协同催化作用,化学需氧量(COD)出水效果得到提高;以Fe^2+/Cu^2+(摩尔比,下同)为1:1或Fe^2+/Cu^2+/Mn^2+为2:2:1复配,与单独使用Fe^2+相比,COD去除率分别提高了13,17个百分点。Styrene - butadiene rubber (SBR) wastewater was pretreated by Fenton reagent,and in- fluence factors were investigated by orthogonal ex- periment. The results showed that hydrogen peroxide amount was the main factor which affected pretreatment efficiency. Each of Cu^2+, BO3^3- and Mn^2+ could complex Fe2. to degrade non biodegradable organics and improve the removal rate of chemical oxygen demand (COD) under the condition of reac- tion temperature 45 ℃, reaction time 60 rain, pH value 3 - 7,1%SO4 ·7 H2O 3. 3 mmol, hydrogen peroxide 4.0 mL and invariable total ion concentra- tion. At Fe^2+/Cu^2+ (mole ratio)1 : 1 or Fe^2+/ Cu^2+/Mn^2+ ( mole ratio) 2 : 2 : 1, COD removal rate increased by 13,17 percent points compared with used Fe^2+.
关 键 词:FENTON试剂 丁苯橡胶废水 混合离子催化剂 化学需氧量 去除率
分 类 号:X703.1[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.149.247.115