TGAS模型及其在建筑火灾中人群安全疏散的应用  被引量:5

TGAS model and its application in building fire about the people safety evacuation

在线阅读下载全文

作  者:冉海潮[1] 焦凤龙[2] 孙丽华[1] 郑斌[3] 

机构地区:[1]河北科技大学,河北石家庄050018 [2]张家口市消防支队,河北张家口075000 [3]石家庄市消防支队,河北石家庄050054

出  处:《消防科学与技术》2013年第11期1209-1211,共3页Fire Science and Technology

基  金:国家自然科学基金资助项目(60874003);河北省自然科学基金项目(601260)

摘  要:采用TGAS模型提出了一种基于人员失能概率的安全疏散评价模型,把人员疏散和人员的失能概率结合在一起,给出了一种基于人员失能概率的多种有毒气体综合作用时危险时间的计算方法。通过算例,在给定失能概率β=0.3的条件下,展示了该评价模型在三种有毒气体综合作用时的工程应用。With the TGAS model, a kind of safety evacuation evaluation model is established based on the probability of the body disability. The evaluation model combined the probability of the body disability with the crowd evacuation. A risk time calculation method with the comprehensive effect of various toxic gases is given based on the probability of the body disabili- ty. When the probability of the body disability β is 0.3, an ex ample of the evaluation model is applied in the comprehensive effect of three kinds of toxic gases.

关 键 词:建筑火灾 人群疏散 烟气毒性 失能 

分 类 号:X913.4[环境科学与工程—安全科学] TU998.12[建筑科学—市政工程]

 