需氧菌阴道炎/细菌性阴道病联合测定技术诊断需氧菌性阴道炎的临床价值  被引量:17

Clinical value of diagnosing aerobic vaginitis by aerobic vaginitis/bacterial vaginosis combined determination technology

在线阅读下载全文

作  者:陈萍 洪开听 陈芬 沈小文 

机构地区:[1]舟山医院定海院区检验科,浙江舟山316000 [2]舟山医院骨伤院区检验科,浙江舟山316000

出  处:《中国微生态学杂志》2013年第11期1346-1347,共2页Chinese Journal of Microecology

摘  要:目的探讨需氧菌阴道炎/细菌性阴道病联合测定技术诊断需氧菌性阴道炎(AV)的临床价值。方法分别采用镜检法和需氧菌阴道炎/细菌性阴道病联合测定技术对200例疑似AV患者进行检测。结果在200例疑似AV患者中,镜检法检出阳性患者174例,需氧菌阴道炎/细菌性阴道病联合测定法检出阳性患者169例。以镜检法为诊断标准,需氧菌阴道炎/细菌性阴道病联合测定技术的敏感性为94.83%、特异性为84.62%。两种方法的符合率为93.50%[(165+22)/200],两者呈中度一致性(Kappa=0.735,P>0.05)。结论需氧菌阴道炎/细菌性阴道病联合测定技术诊断AV具有很高的敏感度和特异度,与目前临床使用的常规镜检法符合率高,且该方法操作简便、快速,值得临床推广使用。Objective To discuss the clinical value of diagnosing aerobic vaginitis (AV) by aerobic vaginitis/bacterial vaginosis combined determination technology. Methods Detection 200 suspected AV patients by microscopic method and aerobic vaginitis/bacterial vaginosis combined determination technology. Results Among 200 suspected AV patients, there were 174 positive patients by microscopic method, there were 169 positive patients by aerobic vaginitis/bacterial vaginosis combined determination technology. With microscopic method as a standard, the sensitivity of aerobic vaginitis/bacterial vaginosis combined determination technology was 94.83%, the specificity was 84.62%. Conformity of two methods was 93.50% [ (165 + 22)/200], and they also showed moderate consistency ( Kappa = 0. 735, P 〉 0.05 ). Conclusion Aerobic vaginitis/bacterial vaginosis combined determination technology has high sensitivity and specificity for diagnosing AV, it has high coincidence rate compare to micro- scopic method used by clinic now, and this technology is simply practised and quick, it is worth that using widely by clinic.

关 键 词:需氧菌阴道炎 镜检 生化检测 诊断 

分 类 号:R466.1[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象