检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:高光珍[1,2] 陈抱雪[1,3] 胡波[2] 龙秀慧[2] 李爱萍[2] 李荣[2]
机构地区:[1]上海理工大学光电信息与计算机工程学院,上海200093 [2]滨州学院物理与电子科学系,理论物理研究所,山东滨州256603 [3]教育部光学仪器与系统工程研究中心,上海市现代光学系统重点实验室,上海200093
出 处:《光谱学与光谱分析》2013年第12期3269-3272,共4页Spectroscopy and Spectral Analysis
基 金:国家自然科学基金项目(61077042,60677032);上海市重点学科项目(S30502)资助
摘 要:可调谐二极管激光吸收光谱技术(TDLAS)具有高分辨率、高灵敏度和快速测量等特点,是气体探测中的主流技术。使用多模二极管激光器作为光源,将多模二极管激光吸收光谱技术与关联光谱技术相结合有助于提高测试可靠性和稳定性,同时还可有效解决单模二极管激光器长时间工作时中心波长随外界温度或机械特性的变化而发生偏移的问题。以1570nrn多模二极管激光器为光源,利用多模二极管激光关联光谱和波长调制的气体测量技术(TMDL-COSPEC-WMS),通过计算待测气体和参考池气体之间二次谐波信号峰值高度之间的关系,实现了对二氧化碳浓度的测量。实验中二氧化碳浓度测量范围在0.6%~30%之间,计算结果表明,二氧化碳浓度与真实浓度值之间具有良好的线性关系,其线性度为0.9987,线性拟合的斜率为1.061±0.0168。对二氧化碳与氮气混合气体的连续测量结果表明,系统的探测极限达到335ppm·m,对同一样品在20min内的20次连续测量的标准偏差为0.0367%,表明了系统良好的稳定性,所有测量结果都显示了系统用于二氧化碳气体监测的有效性。Tunable diode laser absorption spectroscopy (TDLAS) technology is a kind of fast time response, large-range, contin- uous on-line monitoring gas detection technique. It is the mainstream technology of gas detection- In this paper the multimode la- ser diode was used as light source. Multi-mode laser combined with correlation spectroscopy can improve the test reliability and stability. It can also conquer the problem of the central wavelength change of the single mode diode laser due to thermal or me- chanical fluctuations in durable working process. A FP laser was used as the light source in this research. A multi-mode diode la- ser system based on correlation spectroscopy and wavelength modulation spectroscopy (TMDL-COSPEC-WMS) was used to measure carbon dioxide in ambient air around 1 570 nm. The carbon dioxide concentrations were derived from the relationship be- tween the normalized WMS-2f signal peak heights of the measurement and reference signals which selected based on high signal to noise ratio and correlation coefficient. All measurements were performed with controlled carbon dioxide and nitrogen mixtures in which carbon dioxide concentrations range from 0. 6~/oo to 30%. The calculation results showed that there was a high linear re- lationship between the measured and actual carbon dioxide concentration, the linearity was 0. 998 7 and the [itted slope was 1. 061=t=0.016 8 respectively over the tested range. A detection limit of 335 ppm ~ m was achieved. The standard deviation of 0. 036 7% was achieved using 20 successive measurements with each measurement time taking ~10 s during 20 minutes, which demonstrated good stability of the system. Good agreements between the measurements of the system and actual values confirm the accuracy and potential utility of the system for carbon dioxide detection.
关 键 词:可调谐多模二极管激光器 关联光谱 波长调制光谱 二氧化碳浓度
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117