红外光谱内标法测定氯霉素片中氯霉素的含量  被引量:2

Determination of Chloramphenicol in Chloramphenicol Tablets by Internal Standard Method of FTIR

在线阅读下载全文

作  者:彭梦侠[1] 陈梓云[1] 

机构地区:[1]嘉应学院化学系,广东梅州514015

出  处:《化工技术与开发》2013年第11期46-48,58,共4页Technology & Development of Chemical Industry

摘  要:用红外光谱内标法(K3[Fe(CN)6]·6H2O为内标物)测定了氯霉素片中氯霉素的含量。实验表明,混合物红外光谱中氯霉素的测量峰(1686.4cm-1)和K3[Fe(CN)6]·6H2O的内标峰(2117.2cm-1)的峰高比(y=hi/hs)与两者质量比(x=mi/ms)有良好的线性关系,其线性回归方程为y=1.3127x+0.5705,相关系数r=0.9981。据此测得氯霉素片中氯霉素的含量为77.2%,相对标准偏差为1.8%,加标回收率分别为96.8%~103.8%,测定结果与药典规定的紫外分光光度法相近。该方法测量专属性强,无需分离提取,简便、快速、成本低,测定结果准确,特别适合快速批量检测,有应用价值。Potassium ferricyanide was added into chloramphenicol samples as internal reference and the mixtures were measured by Fou-rier transform infrared spectrophotometry (FT-IR). The peak of chloramphenicol at 1686.4 cm-1 was chosen as quantitative peak and the one of potassium ferricyanide at 2117.2 cm-1 was chosen as inside mark quantitative peak. The ratio of two peak’s absorbance (y=hi/hs) had good linear relationship with their mass ratio (x=mi/ms). The linear regression equation was y=1.3127x+0. 5705 with the correlation coef-ficient r=0.9981. The contents of chloramphenicol in the samples of chloramphenicol tablets was 77.2%, the relatively standard deviation was 1.8%, the recoveries of the method was 96.8%~103.8%. This method was highly specific measure, especially for fast batch testing.

关 键 词:红外光谱内标法 氯霉素片 氯霉素 

分 类 号:O657.33[理学—分析化学]

 