某电厂发电机振动故障诊断及处理  被引量:2

Vibration Diagnosis and Disposal for Generator of One Power Plant

在线阅读下载全文

作  者:刘树鹏[1] 张卫军[1] 

机构地区:[1]西安热工研究院有限公司

出  处:《电站系统工程》2013年第6期49-50,共2页Power System Engineering

摘  要:某电厂1号汽轮发电机组自投产后发电机轴承座振动偏大,且处于爬升状态。通过现场详细、全面的测试,诊断其故障原因在于发电机台板和基础间可能存在脱空,利用检修机会对发电机进行了一次现场动平衡工作,使发电机轴承座振动得到了一定改善。最后,给出了进一步改善发电机轴承座振动的具体措施。The generator bearing housing vibration of one power plant No. I unit has been exceeded standard since put into operation and has been in state of gradually climbing. Through exhaustive and comprehensive field test, diagnosing the feasible cause of the malfunction is that there is interval between the generator platen and the base, and then implementing once field dynamic balancing during the overhaul. The generator bearing housing vibration has been certainly improvement. Finally, the further specific measurement has been given, which is used to improve the generator bearing housing vibration.

关 键 词:汽轮发电机组 发电机 台板 振动 动平衡 

分 类 号:TK268.1[动力工程及工程热物理—动力机械及工程]

 