检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《暖通空调》2013年第11期71-74,共4页Heating Ventilating & Air Conditioning
摘 要:结合建筑物的特点,该酒店的空调冷热源采用了水冷离心式冷水机组与燃气蒸汽锅炉;大空间场所设置了全空气空调系统,客房等典型小型房间采用了风机盘管加新风空调系统;空调水系统采用变流量一级泵系统,新风处理采用两管制水系统,其余功能区采用四管制水系统。根据实际能耗监测结果分析了酒店的节能潜力。Considering the features of the hotel, adopts water-cooled centrifugal chillers and gas-fired steam boilers as cold and heat sources of the air conditioning system, installs all-air systems for large space areas and primary air fan-coil system for typical smaller rooms, such as guest rooms, and designs the variable flow distribution with primary pump system for the air conditioning water system with two-pipe system for primary air handling and four-pipe system for other function areas. Based on the actual energy Consumption monitoring data, analyses energy saving potential of the hotel.
关 键 词:冷热源 全空气系统 风机盘管加新风系统 水系统 变流量一级泵系统
分 类 号:TU831.3[建筑科学—供热、供燃气、通风及空调工程]