我国城市污水厂推行一级A标提标改造探讨  被引量:21

DISCUSSION ON UPGRADING RECONSTRUCTION OF MUNICIPAL WASTEWATER TREATMENT PLANT IN CHINA

在线阅读下载全文

作  者:孙晓杰[1] 王嘉捷[1] 赵孝芹[1] 王敦球[1] 朱义年[1] 

机构地区:[1]桂林理工大学环境科学与工程学院 广西环境污染控制理论与技术重点实验室,广西桂林541004

出  处:《环境工程》2013年第6期12-15,共4页Environmental Engineering

基  金:国家重大水专项(2008ZX07317-02);教育部新世纪优秀人才支持计划(NCET-08-0649)

摘  要:一级A标提标改造可削减污染负荷,但也增加能耗。当污水处理率低于100%,削减污染方式包括提高污水处理率和提高污水排放标准。在削减相同污染物条件下,当提标所增能耗小于提高处理率所增能耗时,通过提标削减污染更合理。由于一些地区无法满足这一要求,所以要根据当地污染和当地经济情况,合理推进一级A标提标改造。Upgrading reconstruction (the first class A discharge standard) of municipal wastewater treatment plant can promote reduction of pollutants, but also increase energy consumption. The feasibility of upgrading reconstruction is discussed. In the waste water treatment process, the ways to promote reduction of pollutants include the increase in sewage treatment rate and growing strict regulation on pollutants emission. The pollutants can be reduced by growing strict regulation on pollutants emission, on the condition that the increased energy consumption owing to growing strict regulation on pollutants emission is no more than that owing to the increase in sewage treatment rate, when the same quantity of pollutions are reduced. Because many municipal wastewater treatment plants could not satisfy this requirement, upgrading reconstruction must be coordinated with the local sewage water conditions and local economic conditions.

关 键 词:污水处理厂 提标改造 能耗 节能降耗 

分 类 号:X703[环境科学与工程—环境工程]

 