检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵祥平[1] 王建华[1] 董志珍[1] 王玉玲[1] 王乃福[1] 张永年[1] 刘亚峰[1] 刘红梅[1]
机构地区:[1]天津出入境检验检疫局动植物与食品检测中心,天津300456
出 处:《中国动物检疫》2013年第9期56-58,共3页China Animal Health Inspection
摘 要:为比较ELISA、AGID和PCR方法检测牛白血病的检出率和符合率,本试验采用这三种方法对隔离期间总数为3998头的乌拉圭进口奶牛进行了牛白血病检测。试验结果表明,对奶牛的牛白血病检测以ELISA方法检出率最高,检出牛白血病抗体阳性牛23头,检出率为0.58%(23/3998);AGID方法检出牛白血病抗体阳性牛18头,检出率为0.45%(18/3998),与ELISA方法的符合率为78%;而PCR方法检出牛白血病前病毒核酸阳性牛12头,检出率为0.30%(12/3998),与ELISA方法和AGID方法的符合率分别为43%和55%。To compare the detection rate and coincidence rate of ELISA、AGID and PCR for the detection of bovine leukemia,3998 cows imported from Uruguay were detected by three method during the quarantine period. The test results showed that 23 were positive for bovine leukemia antibody by ELISA with the highest detection rate of 0.58%.18 were positive for bovine leukemia antibody by AGID with the detection rate of 0.45%. 12 were positive for bovine leukemia provirus DNA by PCR with the detection rate of 0.30. The conformation rate of AGID to ELISA is 78%,and the conformation rate of PCR to ELISA and AGID are 43% and 55% respectively。
关 键 词:牛白血病 ELISA AGID PCR 比较试验
分 类 号:S858.23[农业科学—临床兽医学]
正在载入数据...