检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵珊珊[1] 张涛[1] 于洪仕[1,2] 郑丹丹[1]
机构地区:[1]天津大学电气与自动化工程学院 [2]辽宁工程技术大学电子与信息工程学院
出 处:《化工机械》2013年第6期783-787,828,共6页Chemical Engineering & Machinery
摘 要:根据多孔孔板流量计的流场特点选择SST四方程和SST k-ω湍流模型对多孔孔板进行仿真计算,将流出系数计算结果与实流实验结果进行比较。结果表明:相对于SST k-ω湍流模型来说,SST四方程湍流模型更适合计算多孔孔板流量计的流场,而且雷诺数较小时计算精度较高。另外,多孔孔板流量计的环隙比接近1时流出系数线性度最好,达0.8%;环隙比远小于1时流出系数线性度最差,为3.6%。Basing on the flow field characteristics of multi-orifice flow meter, both SST (shear-stress trans- port) 4-equation and SST k-ω turbulence model were selected to simulate multi-orifice flow meter. Having el- flux coefficient' s calculation results compared with experimental results shows that, with respect to SST turbu- lence model, the SST 4-equation turbulence model is more suitable to calculate the flow field of multi-orifice flow meter, and the calculation precision is higher in the case of low Reynolds number; the linearity of the ef- flux coefficient C becomes best and reaches 0.8% when k closes to 1, and oppositely, the linearity of the ef- flux coefficient C becomes worst and reaches 3.6% when k gets less than 1.
分 类 号:TH814[机械工程—仪器科学与技术]