湿冷机组冷端系统节能诊断评价体系的研究  被引量:1

Study on Energy-saving Diagnosis Method for Co1d-End System in Steam Power Unit

在线阅读下载全文

作  者:王浩[1] 于新颖[1] 江浩[1] 吴志强 

机构地区:[1]西安热工研究院有限公司,陕西西安710032 [2]达拉特电厂,内蒙古达拉特014300

出  处:《电站辅机》2013年第4期1-4,13,共5页Power Station Auxiliary Equipment

摘  要:基于冷端系统对湿冷机组经济性影响的重要性,以节能诊断及优化试验数据为基础,从冷端系统整体出发,建立了一套完整的冷端系统节能诊断评价体系。对影响冷端系统性能的各项因素进行了定性和定量研究,研究了冷端系统的最优运行方式,提出相关的节能降耗措施。为冷端系统性能评价和设备状态监测提供了理论依据,具有一定的工程应用价值。Based on the influence of the cold end system on the economical efficiency of wet cooling unit and data of the energy-saving diagnosis and optimization, a complete energy-saving diagnosis evaluation system for cold end system starting from the cold end system. Qualitative and quantitative study have been carried out on all factors influencing the performance the cold end system, the optimal operation mode of cold end system has been studied and measures of energy saving have been put forward. It provides theory basis for the performance evaluation of cold end system and the device state monitoring and has certain engineering application value.

关 键 词:湿冷机组 冷端 系统 节能 诊断 凝汽器 评价 体系 

分 类 号:TM621.7[电气工程—电力系统及自动化]

 