检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张培龙[1] 于丽[1] 庞立飞[1] 侯甲才[1] 贾寿华[1]
机构地区:[1]山东农业大学化学与材料科学学院,泰安271018
出 处:《环境工程学报》2014年第1期242-248,共7页Chinese Journal of Environmental Engineering
基 金:达斯玛环境科技(北京)有限公司资助
摘 要:采用O3/H2O2高级氧化工艺处理炼油厂反渗透(RO)浓水,用溶气泵加压溶气并产生微气泡强化传质,确定装置运行条件,考察气体中臭氧浓度、O3/H2O2初始摩尔比、pH和温度对O3/H2O2处理RO浓水效果的影响,并对RO浓水处理效能进行研究。结果表明,随着气体中臭氧浓度的增加,COD的去除率基本呈线性增加;加入适当量H,0,能提高臭氧氧化RO浓水的效果,O3/H2O2初始摩尔比在0~0.8范围内,COD的去除率先增加后下降,O3/H2O2初始摩尔比为O.5时COD去除率最大;pH从6.84增加到9.01,COD去除率逐渐增大,pH为10.03时COD去除率反而降低;在14~28℃范围内,温度低时,升高温度COD去除率增加较大,温度较高时,升高温度对COD去除率的影响较小。为考察该工艺的稳定性,在H:0:/0,初始摩尔比为O.5、溶液pH为8~9、臭氧浓度为80~100mg/L、温度为10-28℃条件下,对COD为90~140mg/L的RO浓水氧化处理4~10h,出水COD维持在39.9~49.9mg/L,达到《城镇污水处理厂污染物排放标准(GB18918—2002)》中的一级A标准;去除1gCOD消耗031.4~3.3g,消耗0,与H,02的总氧量为2.2~4.4g。Treatment efficiency and influencing factors of refinery reverse osmosis (RO) concentrated water with O3/H2O2 advanced oxidation process were investigated, in which O3/H2O2 process was enhanced by micro- bubble, and microbubble was produced by dissolved air pump. The operating conditions of the device were de- termined. The effects of ozone dosage, the initial mole ratio of H2O/O3, pH and reaction temperature on the degradation of RO concentrated water were discussed. Experimental results showed that the degradation efficiency of COD approximately linearly increased with the increasing ozone dosage. Proper H202 added could improve the degradation efficiency by ozonation. The degradation efficiency firstly increased then decreased when the initial mole ratio of H202/O3 was 0 -0.8, and the optimum initial mole ratio was 0.5. The degradation efficiency in- creased in the range of pH 6.84 - 9.01, but decreased at pH 10.03. Rising temperature the degradation effi- ciency increased observably at low temperature, but the reaction temperature had no remarkable effect on the degradation efficiency at higher temperature in the temperature range of 14 ℃ to 28 ℃. The range of effluent COD were 39.9 - 49.9 mg/L under the conditions of initial mole ratio 0.5, pH 8 - 9, ozone dosage of 80 - 100 rag/L, COD of 90 - 140 mg/L at 10 - 28 ℃ after 4 -10 h. The treated water can meet Category B, Class 1 un- der the standard of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB18918- 2002). Removing 1 g COD consumed 1.4-3.3 g ozone and 2.2-4.4 g total oxygen.
分 类 号:X703[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30