出  处:《化学传感器》2000年第4期14-17,共4页Chemical Sensors

摘  要:本文研究了电聚合金属席夫碱配合物修饰电极对碘离子的选择性响应。Co—salen聚合膜电极对碘离子具有良好的电位响应,响应斜率为—72.5mV/dec,线性范围为2.0×10^(-6)—1.0×10^(-1)mol/L,探讨了聚合膜厚度,pH值对电极性能的影响,同时对电极的响应机理作了进一步的探讨。Potentiometric sensors for iodide ion based on Cu -salen,Co-salen,Mn-salen and Ni-salen film coated glassy carbon electrodes were prepared by electropolymerization method. The Co - salen film electrode showed a slope of - 72. 5mV/dec and a super -Nernst ion potentiometric response to iodide ions over the range of 2×10-6-1.0×10-1 mol/L. The effect of pH,film thickness and the response mechanism are discussed. The electrodes were applied in the determination of iodine in injection preparations.