Ф4000mm大口径钢筋混凝土管接口水密封性能检验方法初探  被引量:3

Test Method Discussion on Water Seal Performance of Interface of Φ4000mm Large Diameter Reinforced Concrete Pipes

在线阅读下载全文

作  者:吕根喜 黄金明 

机构地区:[1]上海浦东混凝土制品有限公司,201202 [2]上海市城市排水有限公司,200233

出  处:《混凝土与水泥制品》2014年第1期24-28,共5页China Concrete and Cement Products

基  金:上海市科委科研项目(11231202400)

摘  要:用于顶进施工的大口径钢筋混凝土管接口的水密封性能检验关乎管线的工程质量。针对上海污水治理南线干管工程对所使用的Ф4000mm承插式钢筋混凝土管接口需达到"零渗漏"的要求,提出了具体的检验方案。检验结果表明,采用环状水压试验架可模拟施工工况条件,进行大口径管材接口的水密封性能检测,特别是接口在允许转角范围内的水密封状况检验。The water seal performance of the interface of the large diameter reinforced concrete pipes is very important, and its test method is the key for the pipeline engineering quality by using the jacking construction method. Interface of φ4000mm socket type reinforced concrete pipes has to achieve the requirement of zero leakage in Shanghai sewage disposal project. For solving this problem, the specific inspection scheme is put forward. The inspection results show that the annular pressure test stand can simulate the construction conditions, and test the water sealing performance of interfaces of the large diameter pipes, particularly within the scope of allowed angle.

关 键 词:大口径混凝土管 接口 水密封性能 检验方法 