检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:范慧群
出 处:《环境监测管理与技术》2013年第6期31-33,共3页The Administration and Technique of Environmental Monitoring
基 金:国家自然科学基金资助项目(51079028);973计划课题基金资助项目(2010CB951102);上海市自然科学基金资助项目(10ZR1400300)
摘 要:采用新型金膜吸附-冷原子吸收光谱法测定空气中的汞,在0μg/L~100μg/L范围内线性良好,相关系数为0.999 1。方法检出限为1.6 ng/m3,RSD为0.5%~2.7%,测定两种不同浓度的汞标准样品,相对误差为6.1%和3.2%。与两种现行国标方法(巯基棉富集和高锰酸钾溶液吸附法)比较,该方法所需试剂种类少,操作简便、吸附效率好,加标回收率高。The new type of gold film adsorption-cold atomic absorption spectrophotometric method was a-dopted to determine mercury in air .Good linearity was obtained within the concentration scope of 0 μg/L^100 μg/L, with the correlation coefficient 0.999 1.The detection limit come to be 1.6 ng/m3 , with the RSDs ranged from 0.5%to 2.7%.Relative errors were 6.1%and 3.2% respectively when two different concentra-tions of mercury standard samples were determined by the current method .Compared this method and the two kinds of the current national standard method ( Enrichment of sulfhydryl cotton and potassium permanganate solu-tion absorption method ) , this method needs less kinds of agents and is easy to handle .Meanwhile , this method show high adsorption efficiency and high spiked recoveries .