鲁米诺-羧甲基壳聚糖化学发光体系测定微量铅离子  

Determination of Picomole Concentration of Pb(II) Using A Luminol-Carboxymethyl Chitosan Chemiluminescence System

在线阅读下载全文

作  者:吴珉[1] 游居东[2] 宋正华[2] 

机构地区:[1]陕西省石油化工研究设计院应用化学品研究所,陕西西安710054 [2]西北大学化学与材料科学学院,陕西西安710069

出  处:《广东化工》2014年第1期154-155,共2页Guangdong Chemical Industry

摘  要:基于Pb(Ⅱ)对鲁米诺(luminol)-羧甲基壳聚糖(CMCS)化学发光体系的抑制作用,建立了操作简便、快速的测定微量Pb(Ⅱ)的方法.在选定的最佳实验条件下,Pb(Ⅱ)在浓度范围0.048~24.1 nmol·mL-1内的对数值与体系化学发光强度变化值呈线性关系,检测限为16.1 pmol·mL-1(3σ).本法成功用于测定水样中的Pb(Ⅱ)含量的测定.A sensitive, simple and rapid flow injection chemiluminescence(CL) method, based on the inhibitory effect of Pb(Ⅱ) on the luminol-carboxymethyl chitosan(CMCS) CL system, was presented for the determination of picomole concentration of Pb(Ⅱ). It was found that the decrease of the intensity was linearly proportional to the logarithm of Pb(Ⅱ) concentration in the range of 0.048 - 24.1 nmol.mL-1 with a detection limit of 16.1 nmol-mL-1(3σ). The proposed method was successfully applied to assay Pb(Ⅱ) in water sample.

关 键 词: 羧甲基壳聚糖 鲁米诺 化学发光 