Experimental Study of Cavitation Phenomenon in a Centrifugal Blood Pump Induced by the Failure of Inlet Cannula  被引量:4

Experimental Study of Cavitation Phenomenon in a Centrifugal Blood Pump Induced by the Failure of Inlet Cannula

在线阅读下载全文

作  者:LIN Zhe RUAN Xiaodong ZOU Jun FU Xin 

机构地区:[1]The State Key Lab of Fluid Power Transmission and Control, Zhejiang University

出  处:《Chinese Journal of Mechanical Engineering》2014年第1期165-170,共6页中国机械工程学报(英文版)

基  金:supported by the National Natural Science Foundation of China(Grant No.51275461);the Zhejiang Provincial Natural Science Foundation of China(Grant No.Z1110189)

摘  要:Cavitation of centrifugal blood pump is a serious problem accompany with the blocking failure of short inlet cannula. However, hardly any work has been seen in published literature on this complex cavitation phenomenon caused by the coupling effect of inlet cannula blocking and pumps suction. Even for cavitation studies on ordinary centrifugal pumps, similar researches on this issue are rare. In this paper, the roles of throttling, rotation speed and fluid viscosity on bubble inception and intensity in a centrifugal blood pump are studied, on the basis of experimental observations. An adjustable throttle valve installed just upstream blood pump inlet is used to simulate the throttling effect of the narrowed inlet cannula. The rotation speed is adjusted from 2 600 r/rain to 3 200 r/min. Glycerin water solutions are used to investigate the influences of kinetic viscosity. Bubbles are recorded with a high-speed video camera. Direct observation shows that different from cavitation in industrial centrifugal pumps, gas nuclei appears at the nearby of vane leading edges while throttling is light, then moves upstream to the joint position of inlet pipe and pump with the closing of the valve. It's found that the critical inlet pressure, obtained when bubbles are first observed, decreases linearly with viscosity and the slope is independent with rotation speeds; the critical inlet pressure and the inlet extreme pressure which is obtained when the throttle valve is nearly closed, fall linearly with rotation speed respectively and the relative pressure between them is independent with rotation speed and fluid viscosity. This paper studies experimentally on cavitation in centrifugal blood pump that caused by the failure of assembled short inlet cannula, which mav beneficial the desima of centrifugal blood Dumo with inlet cannula.Cavitation of centrifugal blood pump is a serious problem accompany with the blocking failure of short inlet cannula. However, hardly any work has been seen in published literature on this complex cavitation phenomenon caused by the coupling effect of inlet cannula blocking and pumps suction. Even for cavitation studies on ordinary centrifugal pumps, similar researches on this issue are rare. In this paper, the roles of throttling, rotation speed and fluid viscosity on bubble inception and intensity in a centrifugal blood pump are studied, on the basis of experimental observations. An adjustable throttle valve installed just upstream blood pump inlet is used to simulate the throttling effect of the narrowed inlet cannula. The rotation speed is adjusted from 2 600 r/rain to 3 200 r/min. Glycerin water solutions are used to investigate the influences of kinetic viscosity. Bubbles are recorded with a high-speed video camera. Direct observation shows that different from cavitation in industrial centrifugal pumps, gas nuclei appears at the nearby of vane leading edges while throttling is light, then moves upstream to the joint position of inlet pipe and pump with the closing of the valve. It's found that the critical inlet pressure, obtained when bubbles are first observed, decreases linearly with viscosity and the slope is independent with rotation speeds; the critical inlet pressure and the inlet extreme pressure which is obtained when the throttle valve is nearly closed, fall linearly with rotation speed respectively and the relative pressure between them is independent with rotation speed and fluid viscosity. This paper studies experimentally on cavitation in centrifugal blood pump that caused by the failure of assembled short inlet cannula, which mav beneficial the desima of centrifugal blood Dumo with inlet cannula.

关 键 词:centrifugal blood pump CAVITATION VISCOSITY cannula diameter rotation speed 

分 类 号:TH38[机械工程—机械制造及自动化]

 