摘 要:目的:通过对中频电治疗中使用的粘贴电极片进行物理性能测试和临床应用效果评价,并与传统导电橡胶电极片相比较,从而全面评价粘贴电极片的临床应用价值,为粘贴电极片用于中频电治疗的推广提供临床研究支持。方法:分别测定导电粘贴电极和导电橡胶电极片的电阻值、进行中频电治疗时的最大输出电流。选取中频脉冲电治疗患者300例,部位分别为面部60例、颈部60例、肩部60例、腰部60例、踝部60例。将选取患者随机分为两组。一组使用粘贴电极片进行中频电治疗,为试验组。一组使用导电橡胶电极片进行中频电治疗,为对照组。分别记录两组患者进行中频电治疗所需操作时间。结果:粘贴电极和传统导电橡胶电极片物理性能测试指标比较差异无统计学意义(P>0.05)。治疗操作时间的测定对比显示:试验组在面部、颈部、肩部、腰背部、踝部治疗所需操作时间均短于对照组,两组比较差异均有统计学意义(P<0.05)。对不良事件统计显示,试验组患者发生皮肤过敏1例,发生率为0.6%,未发生电击、皮肤灼伤等不良事件。结论:使用粘贴电极片进行中频电治疗具有使用方便、操作简单、导电性能好,且卫生、安全等优点。Objective:To explore the effect of the clinical application and the physical performance of paste electrode used in medium frequency electrottherapy(MFE),as well as to compare with the traditional conductive rubber electrode plate,so as to fully evaluate of the clinical application of paste electrode,and to get clinical research support for the spread of the paste electrode on MFE. Method:Respectively tested the resistance and maximum output current at the MFE of the paste electrodes and the conductive rubber electrodes. Selected 300 cases on MFE patients:60 cases on face, 60 cases on neck,60 cases on shoulder,60 cases on waist,60 cases on ankle. Three hundred cases were randomly divided into the treatment group and control group,each group of 150 cases. The treatment group used the paste electrode sheet for MFE. The control group used conductive rubber electrode plate for MFE. The two groups were respectively recorded with MFE required operating time. Result:Paste electrode and the conductive rubber electrode plate of traditional physical performance test had no statistical significance(P〉0.05). The treatment group was better than the control in operating time of the face,neck,shoulder,waist and back,ankle,there was statistical significance in operation time(P〈0.05). The statistics of adverse events showed that 1 case of skin hypersensitivity in the treatment group,the incidence percent was 0.6%,and no electric shock,skin burns and other adverse events. Conclusion:Using the paste electrode sheet for MFE is more convenient,operation is simpler with good conductivity,as well as the advantages of health and safety.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15