Fenton试剂法预处理高氯化工废水的研究  

Study on High-chloride Chemical Wastewater Pretreatment by Fenton Process

在线阅读下载全文

作  者:张文博[1] 刘娟丽[1] 王黎虹[1] 刘兆民[1] 

机构地区:[1]西北民族大学化工学院,甘肃兰州730030

出  处:《西北民族大学学报(自然科学版)》2013年第3期10-12,81,共4页Journal of Northwest Minzu University(Natural Science)

基  金:西北民族大学中青年科研基金项目(XBMU-2008-BD-88);西北民族大学中央高校基本科研业务费专项资金项目(31920130064)

摘  要:采用Fenton试剂预处理高氯化工废水,考察了主要影响因素,确定了最佳工艺参数.结果表明,在pH值为4,H2O2投加量325 mmol,FeSO4投加量20.8 mmol,反应时间90 min的条件下处理250 mL废水,COD去除率达到64%以上,B/C值由0.016提高到0.35,水质得到明显改善,有利于后续生化处理.The high - chloride chemical wastewater was pretreated using Fenton reagent. The dominant influencing factors were discussed and the optimal technological parameters were determined. The results showed that the COD removal rate was more than 64% and the B/C increased from 0. 016 to 0.35 under the conditions of pH value of 4. The dosage of H2O2 was 325 mrnol. The dosage of FeSO4 was 20.8 mmol and the reaction time was 90 min for 250 mL wastewater. The quality of the water was improved obviously and favorable to the latter biochemical processing.

关 键 词:FENTON试剂 高氯化工废水 预处理 