半地下车库火灾情况下通风排烟方式探讨  被引量:2

Discussion on smoke exhaust and air supply mode for semi-underground car park in the case of a fire

在线阅读下载全文

作  者:李宏伟[1] 

机构地区:[1]烟台市消防支队,山东烟台264000

出  处:《消防科学与技术》2014年第1期41-43,共3页Fire Science and Technology

摘  要:以半地下汽车库作为烟气控制研究对象,运用FDS软件模拟计算半地下汽车库发生火灾时产生的烟气在车库内的流动情况,并且通过分析发生火灾时温度和烟气层的能见度、高度等参数研究半地下车库的有效排烟-补风方式。结果表明:在一定的建筑结构、周边环境及地形条件下,可以采用顶部自然排烟口(采光通风井)和高侧窗补风的自然排烟补风方式代替整个防火分区机械排烟设计。Smoke control and air supply mode was studied for a semi-underground ear park of a residential district. Using FDS to calculate the flow of generated smoke by fire in the semi-un- derground car park , and by analyzing the parameters of smokelayer temperature and visibility, carbon monoxide concentra- tions in case of fire, the effective smoke exhaust and air supply mode in semi-underground car park waer investigated. Results show that under certain building structure, the surrounding en vironment and terrain conditions, the natural smoke exhaust and air supply mode can be used in a natural smoke exhaust (day lighting and ventilation shaft) and high side window venti- lation, instead of mechanical smoke exhaust design with the whole fire partition.

关 键 词:半地下车库 烟气控制 排烟-补风方式 数值模拟 FDS 

分 类 号:X913.4[环境科学与工程—安全科学] TU834.1[建筑科学—供热、供燃气、通风及空调工程]

 